Add to Favorites
Share

Movable Flange Assembly-type Thermocouple WRE-330,WRE-331

  • Description
Product Detail


    WRE series assembly-type thermocouple

    Brief Description

    The industrial assembly-type thermocouple is used as a sensor to measure temperature, usually matched with display instruments, recording meter and electronic computer. It can directly measure temperature from 0oC to 800oC of liquid, vapor, gas medium and solid surface during various production processes. In addition, the device has the advantages of simple assembly, convenient replacement, pressure spring type temperature sensing element, good anti-vibration, wide measuring range, high mechanical strength, good pressure durability.

    Working principle

    Thermocouple working principle: two conductors with different components are welded at both ends to form a loop, measuring temperature directly side is called measurement side, terminal side is called reference side. When the temperature between measurement side and reference side has a difference, it will generate heat in the loop current, then connected to the display instrument, And the instrument indicates the corresponding temperature value of the thermal electromotive force generated by the thermocouple. Thermocouple thermoelectric EMF will grow with the measurement temperature’s growth, The size of the thermal electromotive force is related to the temperature of both ends. It has nothing to do with the length, diameter of the thermode.

    Junction box, protective tube, insulated casing, termals and thermal electodes form a basic structure of assembly-type thermocouple, with a variety of installation of fixtures.

    Main technical parameter

    Temperature measurement range and tolerance

    Thermocouple type

    Code

    Graduation

    Measurement range?

    tolerance?t ?

    Nickel chromium 

    WRE

    E

    0~800

    ±2.5??±0.75%¦t¦


    Thermal response time 

    When the temperature appear step change, the thermocouple output variation is to the equivalent of 50% of the change, The time required is called the thermal response time “T0.5”
    The nominal pressure of the thermocouple
    Generally speaking, it is the static outside pressure which the protection tube can withstand without being broken in the room temperature. In fact, allowing working pressure is not only related to the protection tube material, the diameter and wall thickness, it is also related to its structure, the installation method, the into depth, the measured flow rate to its structure, the installation method, the into depth, the measured flow rate and the type of media.
    The test voltage of the insulation resistance in room temperature is DC 500V±50V, The atmospheric conditions of measuring at the room temperature insulation resistance is 15~35?, relative humidity is 45% and atm pressure is 86~106kPa,

    For thermocouples that is longer than 1 meters, the product of the resistance value at ambient-temperature and its length should be not less than 100.
    Can be expressed as: Rr. L?100MO.ML>1m
    Rr here means the insulation resistance value of the thermocouple at ambient-temperature, the unit is MO.
    For thermocouple of which the length is equal to/less than 1m small, its ambient temperature insulation resistance value shall not be less than 100MO.
    Upper-limit temperature of the insulation resistance
    The upper-limit temperature of the isulation resistance for thermocouple should not be less than the following provisons:


         Upper-limit temperature?

    Test temperature t?

     Resistance value MO

    100=tm<300

    t=tm

    10

    300=tm<500

    t=tm

    2

    500=tm<850

    t=tm

    0.5

    850=tm<1000

    t=tm

    0.08

    1000=tm<1300

    t=tm

    0.02

    tm>1300

    t=1300

    0.02

    Model

    WR

    Thermocouple

    Content


    Code

    Heat probe type

    R

    Pt-Rh30- Pt-Rh6

    P

    Pt-Rh 10-Pt

    N

    Nickel chromium-nickel silicon

    M

    Nickel chromium nickel silicon - silicon

    E

    Nickel chromium - nickel copper

    C

    Copper - Copper - Nickel

    F

    Iron copper nickel


    Code

    Output signal number

    None
         2

    single
    double

    Code

    Fixed device form


    1
    2
    3
    4
    5

     7

    Without fixed device
    Fixed threaded
    Movable flange
    Fixed flange
    Movable flange square
    Fixed thread conical
    Straight pipe joint type

    Code

    Terminal type

    2
    3
    4

    Splash proof
    Waterproof type
    Explosion proof type


    Code

    Protection tube diameter

    0

    F16mm

    1

    F25mm

    2

    F16mm

    3

    F20mm

    If the movable flange assembly-type thermocouple wre-330,wre-331 for sale caters to your requirement, welcome to buy with us. As one of the leading such manufacturers and suppliers in China, we will offer you cheap price and excellent services.

Send your message to this supplier
To:  

CEPAI Group Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
Not exactly what you want? One request, multiple quotations Get Quotations Now >>
Related Searches :